Benefits and Harms of Image Processing in Computed Tomography (CT) Images Containing Artifacts

  Share :          
  57

Abstract Computed tomography (CT) is one of the most important modern diagnostic imaging modalities. However, image quality can be degraded by artifacts, which are distortions or false information that do not represent the patient's true anatomy. This article discusses the benefits of image-processing techniques used to reduce these distortions, their potential harms to diagnostic accuracy, and current artificial-intelligence-based trends. Introduction A CT image is mathematically reconstructed from projection data acquired by detectors after X-rays pass through the body. Any inconsistency in this data, whether caused by the patient, the scanner, or the reconstruction algorithm, produces an artifact in the final image (Barrett & Keat, 2004). Artifacts can obscure true pathology or mimic disease that is not present, making their management clinically critical. Common CT Artifacts • Beam hardening: Low-energy photons are absorbed preferentially, causing dark streaks and cupping, commonly seen near the skull base. • Metal artifacts: Caused by implants such as prostheses and dental fillings, appearing as bright and dark streaks. • Motion artifacts: Caused by patient movement, breathing, or cardiac pulsation, appearing as blurring or double contours. • Partial volume effect: Occurs when a single voxel contains more than one tissue type. • Ring artifacts: Caused by a faulty or miscalibrated detector element. • Photon starvation and noise: Occurs when too few photons reach the detectors, particularly in large patients or low-dose protocols. Detailed classifications and causes are available in Boas and Fleischmann (2012) and Hsieh (2015). Image-Processing Techniques 1. Raw-data (sinogram-domain) correction: such as sinogram inpainting to replace metal-corrupted projections (Kalender et al., 1987). 2. Iterative reconstruction: reduces noise and streaks compared with filtered back projection (Geyer et al., 2015). 3. Dual-energy CT and virtual monoenergetic images: reduce beam hardening and metal effects (Albrecht et al., 2019). 4. Metal artifact reduction (MAR) algorithms: numerous commercial and research approaches (Gjesteby et al., 2016; Katsura et al., 2018). 5. Deep learning: convolutional neural networks (CNNs) trained to remove artifacts from images (Zhang & Yu, 2018). Benefits • Improved diagnostic image quality: recovery of tissue detail adjacent to metal implants, such as around hip prostheses or dental work. • Higher diagnostic confidence: fewer false interpretations caused by artifacts that mimic disease (Barrett & Keat, 2004). • Fewer repeat scans: lowering patient radiation exposure, time, and cost. • Potential dose reduction: iterative reconstruction maintains acceptable quality at lower doses (Geyer et al., 2015). [11/25/2026 11:26 AM] أ . حسنين موسى: • Support for treatment planning: radiotherapy and surgical planning require accurate anatomical boundaries. • Faster workflow: AI-driven automation shortens interpretation time. Harms and Risks • Secondary artifacts: some MAR algorithms introduce new streaks or lose detail near the metal (Gjesteby et al., 2016). • Altered texture and reduced resolution: excessive noise reduction yields an over-smoothed, "plastic" appearance that may hide small low-contrast lesions (Geyer et al., 2015). • Distorted Hounsfield units: attenuation values may shift, affecting quantitative measurements and radiotherapy dose calculations (Katsura et al., 2018). • AI hallucination: neural networks may generate anatomical structures or lesions that do not actually exist (Cohen et al., 2018). • Over-reliance on post-processing: this may reduce attention to preventing artifacts at the source, such as patient positioning and scan settings. • Vendor variability: limited generalizability and difficulty comparing results across scanners and studies. • Regulatory and ethical issues: the need for rigorous clinical validation and transparency about AI use in diagnosis. Recommendations 1. Prevention first: optimize positioning, use appropriate scan protocols, and remove removable metal objects. 2. Always review original (unprocessed) images alongside processed ones. 3. Train radiologists and technologists to recognize both primary and secondary artifacts. 4. Subject AI algorithms to rigorous clinical validation before adoption. 5. Document the use of processing techniques in the imaging report. Conclusion Image processing is a powerful tool for improving CT images affected by artifacts, but it is not risk-free. Balancing visual enhancement with true diagnostic fidelity is the cornerstone of safe practice, and it requires technical awareness and careful clinical review. References 1. Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics. 2004;24(6):1679–1691. 2. Boas FE, Fleischmann D. CT artifacts: causes and reduction techniques. Imaging in Medicine. 2012;4(2):229–240. 3. Gjesteby L, De Man B, Jin Y, et al. Metal artifact reduction in CT: where are we after four decades? IEEE Access. 2016;4:5826–5849. 4. Geyer LL, Schoepf UJ, Meinel FG, et al. State of the art: iterative CT reconstruction techniques. Radiology. 2015;276(2):339–357. 5. Katsura M, Sato J, Akahane M, et al. Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. RadioGraphics. 2018;38(2):450–461. 6. Zhang Y, Yu H. Convolutional neural network based metal artifact reduction in X-ray computed tomography. IEEE Transactions on Medical Imaging. 2018;37(6):1370–1381. 7. Albrecht MH, Vogl TJ, Martin SS, et al. Review of clinical applications for virtual monoenergetic dual-energy CT. Radiology. 2019;293(2):260–271. 8. Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987;164(2):576–577. 9. Cohen JP, Luck M, Honari S. Distribution matching losses can hallucinate features in medical image translation. MICCAI 2018. Springer. 10. Hsieh J. Computed Tomography: Principles, Design, Artifacts, and Recent Advances. 3rd ed. SPIE Press; 2015.